Sensor without thermowell

The OPTITEMP TRA/TCA-P14 temperature assembly is available only without thermowell, usually attached with a compression fitting. It can be installed in existing thermowells. It's an all-purpose device since the decision as to the required insertion depth is only necessary immediately prior to installation.

Design: without thermowell

Process connection: Insertion , e.g with compression fitting

Neck tube connection: no necktube forseen

Tip design: straight tip

Diameter: Ø 6mm

Features

  • RTD ≤ 600°C, TC ≤ 1100°C
  • Different heads available, IP54 to IP68
  • Optional head mounted transmitter & display
  • Spring loaded mineral isolated RTD or TC insert
  • Inserts sheath material 316 L or Inconel 600
  • Standard and customised length
  • Ex Approvals:

- ATEX II 1G Ex ia IIC T6 Ga
- ATEX II 1D Ex ia IIIC T145°C Da IP65
- ATEX II 1D Ex ia IIIC T175°C Da IP65 (wire wound resistance sensors)
- ATEX II 1D Ex ia IIIC T185°C Da IP65 (thin film resistance sensors)

Industries

  • Chemical and petrochemical
  • Oil and gas
  • Power generation
  • Machinery
  • Iron and Steel
  • Pulp and paper

Applications

Insertion-type thermometers are particularly well suited to simple measuring tasks under ambient pressure and for low flow velocities in mechanical and plant engineering.